6800W Dual-Fuel 120V/240V Inverter Generator
Financing Available: We offer financing through Affirm. Add your items to the cart, check out, and select Affirm as your payment method.
Affirm allows you to split your purchase into smaller payments with no hidden fees. Eligible purchases can be split into 4 interest-free payments.
More Power.
More Freedom.
The ERAYAK 6800PD portable dual-fuel inverter generator combines gasoline and propane operation with 120V/240V output for RV trips, workshops and selected home backup circuits. Choose remote, one-touch electric or recoil starting. Automatic propane-to-gasoline switching adds flexibility when both fuels are available. Plan loads around 5,000W running on gasoline or 4,500W on propane, not the temporary peak ratings.

Powerful Output. Flexible Control.
More than dual-fuel convenience. Enjoy intelligent fuel switching, full-power generator architecture, flexible voltage selection and clean inverter performance in one portable solution.
Gasoline + Propane
Choose between gasoline and propane to match fuel availability, storage preferences and different power needs.
Auto Fuel Switching
When both fuels are connected and propane pressure becomes insufficient, the system can automatically switch to available gasoline.
120V / 240V Output
Select the appropriate voltage mode for compatible RV, home backup and 120/240V electrical equipment.
Full-Power Design
Designed to support the generator's rated power through suitable output configurations, without a fixed 120V half-power limitation.
3-Way Starting
Remote starting, one-touch electric start and manual recoil backup provide flexible starting options.
Clean Inverter Power
Low-distortion inverter output helps supply clean power to compatible electronics and appliances.
ECO Speed Control
Engine speed adjusts with electrical demand to help reduce fuel consumption and noise at lighter loads.
CO Safety Protection
Integrated CO monitoring supports automatic shutdown when excessive carbon monoxide is detected or a sensor fault triggers protection.
Your Versatile Power Hub.
Dual-voltage AC connections, 120V RV power, everyday household outlets and advanced control features help you manage your generator with confidence.

30A · 120/240V · L14-30R
One NEMA L14-30R locking receptacle for compatible 120/240V equipment and selected household circuits through approved transfer equipment.
Connector: NEMA L14-30R
240V / 30A: 7,200W theoretical receptacle rating
Actual Output: Limited by generator, circuit and fuel ratings.

30A · 120V · L5-30R
One 120V 30A locking receptacle for compatible equipment and RV connections using the included adapter.
Maximum: 3,600W at 120V by receptacle rating
Important: Subject to breaker, generator and fuel limits.

Dual 120V · 20A Outlets
Two standard household-style outlets for compatible appliances, electronics, chargers and power tools.
20A Rating: 2,400W theoretical at 120V per 20A-rated circuit
Important: Observe shared breaker and circuit limits.

30A RV Adapter
The included L5-30P to TT-30R adapter allows compatible 30A RV cords to connect to the generator's L5-30R outlet.
RV Voltage: 120V only
Important: An adapter does not increase generator output or provide 240V power.
SMART CONNECTIONS & CONTROL
Parallel Connection
Built-in parallel connection interface for compatible ERAYAK inverter generator configurations. Designed to support system expansion when paired with approved parallel equipment.
Requirement: Compatible generator models, approved cables and the specified operating procedure
Note: Parallel output capacity depends on the approved setup.
One-Touch Start / Stop
Start or stop the generator using the integrated one-touch electric start/stop button after completing the proper fuel setup.
Stop: Use the same control after disconnecting loads
Backup: Manual recoil starting
Multi-Function Digital Display
Integrated digital monitoring provides operating information through the generator's control panel, helping users track generator status during use.
Purpose: Convenient operating status monitoring
CO Shutoff & Sensor Monitoring
The carbon monoxide protection system can shut down the generator when excessive CO is detected or when a CO sensor fault prevents reliable monitoring.
Yellow CO Indicator: CO sensor fault
Important: The generator must always be operated outdoors.
12V DC · 8.3A Output
Dedicated 12V DC output for compatible manufacturer-approved DC applications.
Current: 8.3A
Protection: DC overload protector
Protection & Grounding
AC overload protection, a dedicated ground terminal and panel status indicators support proper operation and electrical monitoring.
DC: Circuit overload protection
Ground: Dedicated grounding terminal
Power That Fits Your Setup.
Gasoline and propane provide different output ratings. TITAN-style half-power restrictions do not define the 6800PD's full-power generator architecture, but every individual receptacle still has its own current limit.
Gasoline Running Power
Up to 5,000W of continuous rated generator output on gasoline, with 6,800W maximum temporary peak power. The combined load must stay within total and circuit limits.
Propane Running Power
Up to 4,500W of continuous rated output on propane, with 6,100W maximum temporary peak power. Plan connected loads according to the selected fuel.
Flexible Voltage Selection
Select compatible 120V or 240V output configurations. The L14-30R provides dual-voltage connections; use appropriately rated cables and observe electrical-leg balance.
When both fuel sources are correctly connected and propane supply pressure becomes insufficient, the 6800PD's fuel system can automatically transition to gasoline operation. The system prioritizes propane under the conditions described in the owner's manual. Both fuel supplies must be prepared correctly. An uninterrupted transfer is not guaranteed under all operating conditions.
Full-Power Design: The 6800PD is designed to support up to 5,000W total continuous generator output on gasoline, or 4,500W on propane, through appropriate output configurations. This does not mean that any single 120V 30A outlet can deliver the full generator rating. A 120V 30A receptacle is limited to 3,600W by its current rating. The 240V L14-30R has a theoretical receptacle capacity of 7,200W, but actual available output is limited by the selected fuel and generator rating. In 240V setups, distribute 120V loads appropriately across the electrical legs. Always check current, breaker and combined output requirements.
One Generator.
More Possibilities.
From RV camping and outdoor work to selected home backup circuits, ERAYAK 6800PD combines portable dual-fuel power, flexible voltage and convenient starting.
RV Camping
Compatible 30A RV electrical setups
Home Backup
Selected essential household circuits
Jobsite
Compatible tools and equipment
Workshop
Portable workshop power
Electronics
TVs, routers and charging
Plan Your Power.
Explore 10 common appliances and tools ranked by estimated maximum input or starting watts. Always verify actual equipment requirements before connecting.
Power Planning Note: All values are illustrative estimates, not measured specifications of particular appliance models or guarantees of compatibility. Motor-starting surge varies significantly by equipment model, load, voltage and starting method. Heating appliances generally have little or no additional starting surge. The ERAYAK 6800PD provides 6,800W peak / 5,000W continuous power on gasoline and 6,100W peak / 4,500W continuous power on propane. Individual receptacles and circuit breakers have their own limits, which may be lower than total generator capacity. Equipment with starting demand near the generator's peak rating may not start reliably. Verify actual appliance specifications, connected load and electrical-leg balance before use.
Convenient Starts. Flexible Fuel.
Simple starting controls, automatic fuel management, efficient ECO operation and integrated safety monitoring make the 6800PD easier to prepare and operate.
3 Starting Methods
Start with the remote controller, integrated one-touch electric start or manual recoil starter. Follow the fuel selection and preparation procedure in the owner's manual.
Gasoline Runtime
With the 2.9 gal gasoline tank, approximate runtime is: 10–12 hours at 25% load and 7–8 hours at 50% load. Actual runtime varies with operating conditions.
Automatic Fuel Switching
When both fuel sources are connected, the system can prioritize propane and switch to available gasoline if propane pressure becomes insufficient. Follow the manual for correct fuel selection.
Propane Fuel Setup
Includes a propane hose and regulator. Connect a compatible LPG cylinder using the specified equipment. Check connections for leaks before operation.
ECO Mode
ECO adjusts engine speed according to electrical demand to help reduce noise and fuel consumption. Turn ECO off when powering loads with high starting current, such as pumps or compressors.
CO Protection System
Red CO indicator: Excessive carbon monoxide can trigger shutdown. Yellow CO indicator: A CO sensor fault can also cause protective shutdown or prevent starting.
First-Time Battery Setup
Before using electric or remote start for the first time, connect the starting battery wire as illustrated in the owner's manual. Follow the recommended battery charging and storage procedures.
Digital Monitoring
An integrated multi-function digital meter and status indicators help users monitor operation and identify potential system warnings.
Engine Maintenance
223cc gasoline engine with approximately 0.65L engine oil capacity. The recommended oil is SAE 10W-30. Check the engine oil before operation.
Additional Specifications: 12V DC output rated at 8.3A. Product dimensions: approximately 23.8 × 16.7 × 21.5 inches. Net weight: 90.4 lb. Gasoline runtime estimates: 10–12 hours at 25% load and 7–8 hours at 50% load. Actual runtime depends on load, fuel quality, temperature, altitude, ECO mode and maintenance. Published operating noise should be compared using the same measurement distance and load conditions.
Connect Your Power the Right Way.
Use the included RV adapter for compatible 120V 30A recreational vehicle systems. For selected home backup circuits, use the 120/240V L14-30R connection through properly rated, professionally installed transfer equipment.
Prepare Fuel & Loads
Prepare gasoline or propane according to the manual. When using both fuel sources for automatic switching, verify both supplies are connected correctly and safely. Check all planned loads against the selected fuel's output rating.
Connect the RV Adapter
With the generator stopped and RV loads disconnected, connect the included L5-30P to TT-30R adapter to the 120V L5-30R outlet. Connect the compatible 30A RV power cord.
Start & Manage Power
Start using remote, one-touch electric or recoil operation. Allow output to stabilize, then connect and add electrical loads gradually. Monitor connected demand and circuit limits.
120/240V Home Backup Connection
The NEMA L14-30R receptacle can support compatible selected household circuits through a correctly rated inlet and approved transfer switch or interlock. A qualified electrician must verify the installation's voltage requirements, neutral and grounding configuration, electrical-leg balance, current limits and applicable codes. Never backfeed a household wall outlet or connect directly to the utility grid.
RV Compatibility: The included L5-30P to TT-30R adapter is designed for compatible 120V 30A RV connections. It does not provide full 50A RV service, increase generator output or create 240V power through the L5-30R outlet. When using an RV surge protector or transfer system, verify neutral-ground compatibility. Confirm the power cord, adapter and connected appliance ratings before use.
Operate the generator outdoors only, at least 20 ft from doors, windows and vents, with exhaust directed away from occupied buildings. Never run the generator inside an RV, tent, home, garage, shed or any enclosed or partially enclosed space. Always use working carbon monoxide alarms. The CO shutdown system is an additional protective feature and does not make enclosed operation safe. Keep the generator and all electrical connections dry. Never operate in rain, standing water or flooded conditions. Connect LPG hoses and regulators correctly and check for leaks before operation. Never refuel a hot or running generator. Follow the owner's manual for fuel switching, battery connection, ECO operation and overload procedures. Use approved extension cords, adapters and transfer equipment. Follow the current ERAYAK 6800 Series owner's manual and all applicable electrical safety requirements.
You may also like
Find what you need
It's not good-bye.
It's catch ya on the flip side🤘